snmp-view¶
The following operations can be performed on "snmp-view":
add snmp view¶
Adds an SNMPv3 view. Used to implement access control for the SNMPv3 user, SNMPv3 views restrict user access to specific portions of the MIB. The Citrix ADC can have multiple SNMPv3 views with the same name, differentiated by subtree parameter settings. You can add a maximum of 1000 SNMPv3 views.
Synopsis¶
add snmp view <name> <subtree> -type ( included | excluded )
Arguments¶
name
Name for the SNMPv3 view. Can consist of 1 to 31 characters that include uppercase and lowercase letters, numbers, and the hyphen (-), period (.) pound (#), space ( ), at sign (@), equals (=), colon (:), and underscore (_) characters. You should choose a name that helps identify the SNMPv3 view.
The following requirement applies only to the Citrix ADC CLI: If the name includes one or more spaces, enclose it in double or single quotation marks (for example, "my view" or 'my view').
subtree
A particular branch (subtree) of the MIB tree that you want to associate with this SNMPv3 view. You must specify the subtree as an SNMP OID.
type
Include or exclude the subtree, specified by the subtree parameter, in or from this view. This setting can be useful when you have included a subtree, such as A, in an SNMPv3 view and you want to exclude a specific subtree of A, such as B, from the SNMPv3 view.
Possible values: included, excluded
rm snmp view¶
Removes an SNMPv3 view entry from the Citrix ADC. The appliance can have multiple SNMPv3 views with the same name, differentiated by the subtree parameter setting. Therefore, to identify an SNMPv3 group subtree that you want to remove, you have to specify both the name and subtree of the SNMPv3 view.
Synopsis¶
rm snmp view <name> <subtree>
Arguments¶
name
Name of the SNMPv3 view. Note: If multiple views have the same name, specify the subtree to identify the view to be removed.
subtree
A MIB subtree of the SNMPv3 view.
set snmp view¶
Modifies the type (Type) parameter of an SNMPv3 view configured on the Citrix ADC.
Synopsis¶
set snmp view <name> <subtree> -type ( included | excluded )
Arguments¶
name
The name specified in the SNMPv3 view entry. This parameter cannot be modified.
subtree
A MIB subtree of the SNMPv3 view entry. This parameter cannot be modified.
type
Include or exclude the subtree, specified by the subtree parameter, in or from this view. This setting can be useful when you have included a subtree, such as A, in an SNMPv3 view and you want to exclude a specific subtree of A, such as B, from the SNMPv3 view.
Possible values: included, excluded
show snmp view¶
Displays the settings of all SNMPv3 views or of the specified SNMPv3 view. To display the settings of all the SNMPv3 views, run the command without any parameters. To display the settings of a particular SNMPv3 view, specify the name of the SNMPv3 view and subtree (the associated subtree of the MIB). The Citrix ADC can have multiple SNMPv3 views with the same name, differentiated by the subtree parameter settings.
Synopsis¶
show snmp view [<name> [<subtree>]]
Arguments¶
name
Name of the SNMPv3 view.
subtree
A MIB subtree of the SNMPv3 view.
Output¶
type
The type of sutree.
storageType
The storage type for this view.
status
The status of this view.
devno
count
stateflag